General
© ekey biometric systems GmbH Operating instructions ekey home Page 25 / 41
8.2.2.2
MAIN MENU
The main menu items and thus the most important programming steps are
Enroll user – add new user and enroll the corresponding fingerprints
Delete user – delete all data of a certain user
Logging - displays the last 50 accesses
Security code – change the security code to enter the menu
Change relay
Switching time – change the switching time of the relay output
Reset – reset to factory settings
Test mode – test mode for simplified commissioning
LED intensity - sets the intensity of the status LED on the finger scanner
8.2.2.3
INITIAL OPERATION
Before you connect the system to the mains, make sure that both the mounting and the
wiring have been done correctly.
You may only manipulate the electric connections after having separated the system
from the mains!
CAUTION! The electrical connection of the system can only be carried out by a
specialist!!!
CONNECTION BETWEEN CONTROL PANEL AND FINGER SCANNER
When the devices are connected to the power supply, the language selection is displayed on the ekey
home CP DRM. Once the boot procedure on the ekey home FS has been completed, the status LED of the
finger scanner begins flashing in orange or blue colour.
Now the initialization can be started.
DISPLA Y KEY
STROKE
DISPLA Y KEY
STROKE
DISPLA Y KEY
STROKE
DISPLA Y KEY
STROKE
DISPLA Y
OR
NEW = new system =
finger scanner and control
panel have the factory
default settings!
If you have only replaced the ekey home CP DRM, and
you are using an ekey home finger scanner on which fingers
have already been saved (e.g. replacement due to a
defective CP), you can keep all the saved fingers by
swiping a saved finger over the sensor. If you strike the
ESC key, then all the fingers will be deleted!
F
I
N
I
S
E
D