General
© ekey biometric systems GmbH Operating instructions ekey home Page 23 / 41
8.2.1.12
RESETTING TO FACTORY SETTINGS
If you carry out this procedure, then all the saved data will be irrecoverably deleted!
If you reset the device to its factory settings, all the user data (user fingers) in the memory are deleted.
The security code is reset to the standard value of 99, the control panel and the finger scanner are
disconnected, and the relay switching times are set for all the relays at 3s.
1.)
First enter the security code as per section 8.2.1.6.
2.)
Press the > button until “rr” is displayed
3.)
Press the OK button
4.)
Enter the left digit of the security code using the < and > buttons
5.)
Press the OK button
6.)
Enter the right digit of the security code using the < and > buttons
7.)
Press the OK button
8.)
After a couple of seconds, “rr” is displayed and then two red dots appear on the display. The LED
on the finger scanner flashes orange. The device is now reset to its factory settings (= as when it
was delivered).
To start operating the device again, proceed from section 8.2.1.4. You must re-initialize the devices.
ENTER SECURITY
CODE
DISPLA Y +
SETTING
KEY STROKE DISPLA Y +
SETTING
KEY STROKE DISPLA Y +
SETTING
KEY STROKE DISPLA Y DISPLAY
SEE B:
ITEM rr
DIGIT 1
DIGIT 2
Your device has now
been reset to its factory
settings!
STA RT