EKey Fingerscan Access Control System Uživatelský manuál Strana 12

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 11
1 Finger scanner wall-mounted WM 2.0
Part No. Description Model
101 405 ekey home FS WM 2.0 silver-metallic
FAR: 1:10.000.000
FRR: 1:100
Dimensions W/H/D:
45 x 81,6 x 60,3 mm
Power consumption ca. 1 W
Supply voltage:
8-24 VAC, 8-30 VDC
Temperature range: -25° C up to +70° C
IP rating: IP44
Recommended installation height: 135 cm
Display: 3 multicolor LEDs
Functions: 99 ngers storable, tamper-proof, data
not lost in case of power failure, bus termination
congurable on device
Compatible with system >
ekey home
ekey multi
2 Accessories WM 2.0
Weather shield for wall-mounted scanner
101 406 ekey weather shield WM 2.0 ED Brushed stainless steel
Dimensions W/H/D:
110 x 170 x 95 mm
Recommended installation height:
130 cm (lower ledge)
Stainless steel adapter for wall-mounted scanner
101 418
ekey cover WM 2.0 ST for installation
at 110 cm (lower edge)
Brushed stainless steel
Dimensions W/H/D:
89 x 87 x 103 mm
optionally
ekey home
ekey multi
Compatible with system >
3 Control panels
Part No. Description Model
ekey home wall-mounted control panel
100 478 ekey home CP WM 1 1 relay
100 479 ekey home CP WM 3 3 relays
Dimensions W/H/D:
180 x 110 x 39.2 mm
Power consumption: approx. 1 W
Supply voltage: 9-12 VAC/DC
Temperature range: -20° C up to 70° C
IP rating: IP20
Relays:
CP 1: 1 output, dry contact
CP 3: 3 outputs, dry contacts
Max. relay input voltage, input current:
250 VAC/5A; 30 VDC/5A
Inputs (exit button): -
Display: LED 2x7 segments
Programming: 4 push buttons
RS485 termination: not congurable
Functions: Enroll users, delete users, change relay
opening times (0-99s),
adjustable security code, reset
ekey home DIN-rail mounted control panel
101 162 ekey home CP DRM 1 1 relay
101 312 ekey home CP DRM 2 2 relays
Dimensions W/H/D:
70 (4HP) x 86 x 54 mm
Power consumption: approx. 1 W
Supply voltage: 8-24 VAC/DC
Temperature range: -20° C up to 70° C
IP rating: IP20
Relays:
CP DRM 1: 1 output, dry contact
CP DRM 2: 2 outputs, dry contacts
Max. relay input voltage, input current:
42 VAC/DC; 2A
Inputs (exit button):
CP DRM 1: 1 contact
CP DRM 2: 2 contacts
Display: LCD 106 x 56 pixels,
7 lines/21 characters + 2/4 status-LEDs
RS485 termination: congurable
Functions: Enroll users, delete users, name entries,
change relay times (0-99s), adjustable security code,
reset, test mode
ekey home
Compatible with system >
ekey home